D3000 and D4000

D3000 and D4000

分  类:测量测试仪器

品  牌:欧米茄

厂  商:Omega工业测量(中国)

型  号:D3000 and D4000

相关行业:

发布时间:2019-12-19 16:46 浏览人数:

最新产品

产品详情
参数
包装
  • Analog Output Ranges: 0-1 V, ±1 V, 0-5 V, ±5 V, 0-10 V, ±10V, 0-20 mA, 4-20 mA
  • Programmable High/Low Output Limits
  • 500 V rms Output Isolation
  • Scaling in Engineering Units
  • 12-Bit Resolution
  • Baud Rates: 300 to 38,400
  • Output Protection: 240 Vac (CurrentOutput), ± 30 V (Voltage Outputs)

  • The D3000 and D4000 computer-to-analog outputinterfaces are designed to be mounted remotelyfrom a host computer and communicate withstandard RS-232 and RS-485 serial ports. SimpleASCII commands are used to control a 12-bitdigital-to-analog converter that is scaled to provide commonly used current and voltage ranges.An on-board microprocessor provides thecommunications interface and many intelligentanalog output functions. These modules offer anextremely flexible, easy-to-use, and cost-effective approach to data acquisition. The D3000 and D4000 are compatible with theOMEGABUS®D1000 and D2000 and may be used inany combination. Up to 124 modules may be strung onone set of wires. All modules are supplied with screwterminal plug connectors and captive mountinghardware. The connectors allow system expansion,reconfiguration, or repair without disturbing field wiring.Their small size allows them to be mounted in virtuallyany location or position including explosion-proofhousings and DIN rails. Utility software (D1000-SW)is available upon request at no charge on anIBM-compatible disk.The D4000 modules offer several additionalfeatures. A slew rate may be programmed,which causes the output to ramp at anadjustable rate in either an increasing ordecreasing direction. The ramp can be initiatedand maintained by commands from thecomputer or with external switch closures to themodule. The D4000 module provides areadback feature which allows the computer toverify the integrity of the output.The D4000 modules also include a watchdogtimer circuit that can be set such that if thecomputer fails to communicate with the moduleafter a preset time period, the module will resetitself to an adjustable default value. This featureminimizes the risks of communication failure.The A1000 RS-232 to RS-485 converter and repeatercan be used if an RS-485 port is not available in yourPC, and it is necessary to communicate long distancesaway. The A1000 also provides power for the modules.RS-232 modules can be used for distances less than50 feet.

    Common Specifications, D3000 and D4000 ANALOG OUTPUT
    • Single channel analog output
         Voltage: 0-1 V, ± 1 V, 0-5 V, ± 5 V, 0-10 V, ± 10 V
         Current: 0-20 mA
    • Input isolation to 500 V rms
    • 12-bit measurement resolution
    • Accuracy (integral and differential non-linearity): 0.1% FSR (max)
    • Zero drift: ±30 µV/°C (voltage output)±1.0µA/°C (current output)
    • 1000 conversions per second
    • Settling time to 0.1% FS 300 µs typical (1 ms max)
    • Programmable output slew rate: 0.01 V/s (mA/s) to 10,000 V/s (mA/s) (D4000 only)
    • Autozero and autocalibration-no adjustment pots
    • Voltage compliance: ±12 V
    • Output current, short circuit current: 5 mA min, 10 mA max

    ANALOG OUTPUT READBACK (D4000)
    • 8-bit analog-to-digital converter

    DIGITAL INPUTS
    • Voltage levels: ±30 V without damage
    • Switching levels: High, 3.5 V min, low, 1.0 V max
    • Internal pull-up resistors for direct switch input

    COMMUNICATIONS
    • RS-232, RS-485
    • Up to 124 modules with A1000 converter/repeater, 32 without A1000
    • User selectable channel address (via software command)
    • Selectable baud rates: 300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K
    • ASCII format command/response protocol
    • Parity: odd, even, none
    • All communications setups (address, baud rate,parity) stored in nonvolatile memory using EEPROM
    • Checksum can be added to any command or response
    • Communications distance up to 10,000 feet with RS-485 modules

    Power Requirements: Unregulated +10 V to +30 Vdc, 0.75 W max (voltage output), 1.0 W max (current output)
    Case: ABS with captive mounting hardware
    Connectors: screw terminal barrier plug (supplied)
    Temperature Range: Operating: -25°C to 70°C
    Storage: -25°C to 85°C
    Relative Humidity: 0 to 95% non-condensing

    Model No.Output RangeInput
          D3000 Series Output Module - Voltage Output
    D3121± 1 VRS-232C
    D3122± 1 VRS-485
    D3131± 5 VRS-232C
    D3132± 5 VRS-485
    D3141± 10 VRS-232C
    D3142± 10 VRS-485
    D31610 to 1 VRS-232C
    D31620 to 1 VRS-485
    D31710 to 5 VRS-232C
    D31720 to 5 VRS-485
    D31810 to 10 VRS-232C
    D31820 to 10 VRS-485
          D3000 Series Output Module - Current Output
    D32510 to 20 mARS-232C
    D32520 to 20 mARS-485
          D4000 Series Output Module - Voltage Output
    D4121± 1 VRS-232C
    D4122± 1 VRS-485
    D4131± 5 VRS-232C
    D4132± 5 VRS-485
    D4141± 10 VRS-232C
    D4142± 10 VRS-485
    D41610 to 1 VRS-232C
    D41620 to 1 VRS-485
    D41710 to 5 VRS-232C
    D41720 to 5 VRS-485
    D41810 to 10 VRS-232C
    D41820 to 10 VRS-485
          D4000 Series Output Module - Current Output
    D42510 to 20 mARS-232C
    D42520 to 20 mARS-485












































暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元