OM-NET-TC

OM-NET-TC

分  类:其它

品  牌:欧米茄

厂  商:Omega工业测量(中国)

型  号:OM-NET-TC

相关行业:

发布时间:2019-12-19 17:58 浏览人数:

最新产品

产品详情
参数
包装
  • Eight 24-Bit Differential Thermocouple Inputs with Thermocouple Channel-to-Host Isolation
  • 4 Samples/Sec Channel Maximum Sample Rate
  • Two Integrated Cold Junction Compensation (CJC) Sensors
  • Open Thermocouple Detection
  • 8 Digital I/O Isolated From Thermocouple Inputs and Host
  • Digital Outputs Have ±24 mA Drive Capability and are Configurable as Thermocouple Alarms
  • 10/100 Ethernet Interface

  • The OM-NET-TC thermocoupleinput data acquisition moduleoffers high-accuracy temperaturemeasurement with an Ethernetinterface. The device offers thebest value per channel and thebest possible accuracy becausethe accuracy of the internalmeasurement electronics exceedsthe accuracy specifications ofthe thermocouple sensors. TheOM-NET-TC is functionallyequivalent to an OMEGATM OM-USB-TCmodule (USB interface to computer)which makes application migrationvery easy.

    Ethernet InterfaceThe OM-NET-TC has a built-in highspeedcommunication port. Userscan remotely access and configurethe device with software over theInternet.

    Thermocouple InputConnect up to eight differentialthermocouple (TC) input channelsto the OM-NET-TC. The OM-NET-TCsupports a maximum sample rate of4 S/s per channel, and thermocoupletypes J, K, T, E, R, S, B and N.Thermocouple types are softwareselectableper channel.

    Cold-JunctionCompensationThe OM-NET-TC has twohigh-resolution cold-junctioncompensation (CJC) sensors (oneper four thermocouple inputs).

    Open-ThermocoupleDetectionThe OM-NET-TC is equipped withopen-thermocouple detection(OTD) for all thermocouple inputchannels. With OTD enabled,users can monitor for broken ordisconnected thermocouple inputs.

    Digital I/OThe OM-NET-TC has eight digitalI/O channels that are electricallyisolated from the analog circuits.Each bit is individually configurablefor input or output. Data can betransferred at rates up to 5 kS/swhen the device and host areconnected by Ethernet to the samelocal network. Typical throughputis system-dependent. All DIOchannels are pulled high by defaultto 5V through 47 kO resistors witha jumper on the circuit board. Eachjumper configures the digital portfor pull-up or pull-down.

    Temperature AlarmsEach digital output can beoptionally configured as an alarmfor each thermocouple input.When an alarm is enabled, theoutput line associated with thealarm is driven to the appropriatestate determined by the alarmoptions and input temperature.Use the alarm outputs to control adevice or application that indicateswhen a temperature threshold hasbeen exceeded, or to indicate anopen thermocouple condition.

    Counter InputThe 32-bit event counter pincounts TTL pulses, and acceptsfrequency inputs up to 10 MHz.

    PowerThe OM-NET-TC requires externalpower from the 5V, 1A poweradapter (OM-NET-PS) includedwith the device.

    CalibrationThe OM-NET-TC is factorycalibratedusing a NIST-traceablecalibration process. Specificationsare guaranteed for one year.For calibration beyond one year,Contact Omega and return thedevice for recalibration.

    SoftwareThe OMB-NET-TC moduleships with an impressive arrayof software, including the newTracerDAQ®, a full-featured, out-ofthe-box data logging, viewing, andanalysis application. Driver supportand detailed example programsare included for Universal Libraryprogramming libraries for Microsoft®Visual Studio® programminglanguages, and other languages,including DASYLab®, and ULx forNI LabVIEW® (comprehensivelibrary of VIs and exampleprograms compatible with 32-bit and 64-bit LabVIEW 2010 orlater) and InstaCalTM installation,calibration and test utility-powerfulsolutions for programmers andnonprogrammers alike. Thesemodules operate under MicrosoftWindows® VISTA/7/8/10 (32-bit and64-bit) operating systems.The OMB-NET-TC data acquisitionmodule is supplied with TracerDAQsoftware which is a collection offour virtual instrument applicationsused to graphically display andstore input data and generateoutput signals:
        • Strip Chart—Log and graphvalues acquire from analoginputs, digital inputs, temperatureinputs and counter inputs
        • Oscilloscope—Display valuesacquired from analog inputs
        • Function Generator—Generatewaveforms for analog outputs
        • Rate Generator—Generatewaveforms for counter outputsTracerDAQ PRO is an enhancedversion of TracerDAQ and isavailable as a purchased upgrade(SWD-TRACERDAQ-PRO).A comparison of some of thefeatures included in TracerDAQ vsTracerDAQ Pro (see Spec page PDF).

    Specifications
    (Typical for 25°C unlessotherwise specified)
    THERMOCOUPLE INPUT
    A/D Converter Type: Delta-Sigma
    A/D Resolution: 24-bit
    Number of Channels: 8 differentialchannels
    Isolation Between Any ThermocoupleInput Channel and Digital/Chassis
    Ground: 500 Vdc absolute max
    Channel Configuration: Software selectablefor thermocouple typesJ, K, T, E, R, S, B, N (factory defaultconfiguration is type J). Channelconfiguration is stored on EEPROMexternal to the isolated microcontrollerby the firmware whenever any item ismodified. Modification is performed bycommands issued from an externalapplication, and the configuration ismade non-volatile through the use ofthe EEPROM.
    Differential Input Voltage Range:±0.128V (calibration is performed at±70 mV)
    Absolute Maximum Input Voltage(Between any Two TCx Inputs): ±25V(power on), ±25V (power off)
    Differential Input Impedance: 40 MΩ
    Input Current:
        Open Thermocouple DetectDisabled: 1 nA
        Open Thermocouple DetectEnabled: 65 nA
    Common Mode Rejection(fin = 50 Hz or 60 Hz): 110 dB
    Noise Rejection(fin = 50 Hz or 60 Hz): 75 dB
    Input Bandwidth: 10 Hz
    Crosstalk Between Any TwoThermocouple Inputs: -90 dB
    Sample Rate: 4 Hz max (per channel).The enabled thermocouple inputs arecontinuously converted at the maximumA/D converter rate. If channels areenabled and have an open thermocoupleconnection the sampling rate will be lower.
    Input Noise: 250 nV rms
    Gain Error: 0.006% FSR
    Offset Error: 3 µV
    Measurement Sensitivity (SmallestChange in Temperature That Can BeDetected):
    Thermocouple Type J,K,T,E,N: 0.09°C
    Thermocouple Type R,S: 0.11°C
    Thermocouple Type B: 0.13°C
    Warm-Up Time: 20 minutes min
    Open Thermocouple Detect ResponseTime: 1 s
    CJC Sensor Accuracy (0 to 45°C):±0.20°C typ, ±0.40°C max
    DIGITAL I/O
    Digital Type: 5V TTL input/ CMOSoutput
    Number of I/O: One port of 8 bits,shared with temperature alarmsConfiguration: Each bit can beindependently configured for input oroutput
    Pull-Up Configuration: All pins pulledup to 5V using 47 K resistors (default).Can be changed to pull-down using aninternal jumper
    Digital I/O Transfer Rate (System-Paced): 100 to 5000 port reads/writesor single bit reads/writes per secondtyp, on local network. This is the typicalthroughput when the device and host areboth connected by Ethernet to the samelocal network. The throughput can varysignificantly, and typical throughput isnot guaranteed if a wireless connectionis involved or data is sent over theinternet
    Alarm Functionality: Any combinationof DIO bits may be configured to becomeoutputs and go to defined values whenan Ethernet connection with a host isestablished or lost
    Power On and Reset State: All bits areinput unless the alarm functionality isenabled for them
    Input High Voltage Threshold: 2.0V min
    Input High Voltage Limit: 5.5V absolutemax
    Input Low Voltage Threshold: 0.8V max
    Input Low Voltage Limit: -0.5V absolutemin, 0 V recommended min
    Output High Voltage: 4.4V min(IOH = -50 µA), 3.76V min(IOH = -24 µA)
    Output Low Voltage: 0.1V max(IOL = 50 µA), 0.44V max (IOL = 24 µA)
    Power On and Reset State: Input
    TEMPERATURE ALARMS
    Number of Alarms: 8 (one per digitalI/O line)
    Alarm Functionality: Each alarmcontrols its associated digital I/O lineas an alarm output. When an alarm isenabled, its associated I/O line is setto output and driven to the appropriatestate determined by the alarm optionsand input temperature. The alarmconfigurations are stored in non-volatilememory and loaded at power on
    Alarm Input Modes:
        • Alarm when input temperature =T1,reset alarm when input temperature < T2
        • Alarm when input temperature =T1,reset alarm when input temperature>T2
        • Alarm when input temperature is T2
        • T1 and T2 may be independently setfor each alarm
    Alarm Error Modes:
        • Alarm on temperature reading only
        • Alarm on temperature reading oropen thermocouple error
        • Alarm on thermocouple error only
    Alarm Output Modes:
        • Disabled, digital I/O line may be usedfor normal operation
        • Enabled, active high output (DIO linegoes high when alarm condition is met)
        • Enabled, active low output (DIO linegoes low when alarm condition is met)
    Alarm Latency: 1 second (Alarmsettings are applied when changedand at power-ON. Temperaturesare converted on enabled channelsand processed for alarm conditionsregardless of the communicationsconnectivity)
    COUNTER
    Pin Name: CTR
    Counter Type: Event counter
    Number of Channels: 1
    Input Type: Schmitt trigger, 47 kO pulldownto ground
    Input Source: CTR screw terminalResolution: 32 bits
    Schmitt Trigger Hysteresis: 0.6V min,1.7V max
    Input High Voltage Threshold: 1.9Vmin, 3.6V max
    Input High Voltage Limit: 5.5Vabsolute max
    Input Low Voltage Threshold: 1.0Vmin, 2.3V max
    Input Low Voltage Limit: -0.5Vabsolute min, 0V recommended min
    Input Frequency: 10 MHz max
    High Pulse Width: 50 ns min
    Low Pulse Width 50 ns min
    MEMORY
    EEPROM: 4096 bytes
    POWER
    External Power Supply: 5V, 1A (viaincluded AC adapter)
    Supply Current (Quiescent Current):177 mA typ (this is the total quiescentcurrent requirement for the device thatincludes the LEDs and does not includeany potential loading of the digital I/Obits or +VO terminal
    User Output Voltage Range(Available at +VO Terminal): 4.40Vmin to 5.25V max, assumes suppliedAC adapter is used
    User Output Current (Available at+VO Terminal): 10 mA max
    NETWORK
    Ethernet ConnectionEthernet Type: 100 Base-TX,10 Base-T
    Communication Rates: 10/100 Mbps,auto-negotiated
    Connector: RJ-45, 8 position
    Cable Length: 1 meter standard and upto 100 meters (328') max
    Additional Parameters: HP auto-MDIXsupport
    NETWORK INTERFACE
    Protocols Used: TCP/IP (IPv4 only), UDP
    Network Ports Used: UDP:54211(discovery), UDP:6234 (bootloaderonly), TCP:54211 (com¬mands)Network IP Configuration: DHCP + linklocal,DHCP, static, link-local
    Network Name: E-TC-xxxxxx, wherexxxxxx are the lower 6 digits of thedevice MAC address
    Network Name Publication: By NBNS(responds to b-node broadcasts,therefore only available on the localsubnet)
    NETWORK FACTORYDEFAULT SETTINGS
    Factory Default IP Address:192.168.0.101
    Factory Default Subnet Mask:255.255.255.0
    Factory Default Gateway: 192.168.0.1
    Factory Default DHCP Setting: DHCP+ link-local enabled
    NETWORK SECURITY
    Security Implementation: TCPsockets are not opened unlessapplication sends the correct PIN code(stored in non-volatile memory, may bechanged by user, default value 0000)
    Number of Concurrent Sessions: 1
    Vulnerabilities: TCP sequence numberapproximation vulnerability
    LED DISPLAYS AND THEFACTORY RESET BUTTON
    Factory Reset Button: Used to resetthe network configuration settings to thefactory default values.
    Power LED (Top) 4.2V < Vext <5.6V: On
    Vext <4.2V, Vext >5.6V: Off (power fault)
    Activity LED (Bottom): On when thereis a valid host connection and blinkswhen a command is received
    Ethernet Connector LEDs Left, Green:Link/activity indicator; on when there isa valid Ethernet link and blinks whennetwork activity is detected.
    Right, Yellow: Speed indicator; on for100 Mbps, off for 10 Mbps or no link.
    ENVIRONMENTAL
    Operating Temperature Range:0 to 55°C max (32 to 131°F)
    Storage Temperature Range:-40 to 85°C max (-40 to 185°F)
    Humidity: 0 to 90% RH non-condensingmax
    Screw Terminal ConnectorsConnector Type: Screw terminal
    Wire Gauge Range: 16 to 30 AWG
    MECHANICAL
    Dimensions:117.9 L × 82.8 W × 29.0 mm H(4.64 × 3.26 × 1.14")
    Weight: 0.4 kg (0.88 lb)















































































































暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!