  • 8 Thermocouple Input Channels
  • Supports Thermocouple Types J, K, T, E, N, R, S, B
  • Built-In Cold Junction Compensation and Open Thermocouple Detection
  • Eight Digital I/O–User Configuration for Alarms
  • 802.15.4 Wireless Protocol
  • Range: Up to 46 m (150') Indoors and 732 m (2400') Outdoors

  • The OM-WLS-TC is a wireless USB2.0 full-speed thermocouple inputmodule (fully compatible with bothUSB 1.1 and 2.0). The OM-WLS-TCprovides 8 differential thermocoupleinput channels. Eight independent,TTL compatible digital I/O channelsare provided to monitor TTL levelinputs, communicate with externaldevices and to generate alarms.The digital I/O channels are softwareprogrammable for input or output.The OM-WLS-TC supports Types J,K, T, E, N, R, S and B thermocouples.Two integrated cold junctioncompensation (CJC) sensors areincluded for thermocouplemeasurements. An openthermocouple detection featureallows detection of a brokenthermocouple. An onboardmicroprocessor automaticallylinearizes the measurement data.The OM-WLS-TC features 8independent temperature alarms.Each alarm controls an associateddigital I/O channel as an alarmoutput. The input to each alarm isone of the temperature channels.The output of each alarm issoftware configurable as active highor low. The temperature thresholdconditions to activate each alarmare software programmable. Whenan alarm is activated, theassociated digital output channel isdriven to the output state. Allconfigurable options are softwareprogrammable. The OM-WLS-TC isfully software-calibrated.

    The OM-WLS-TC can be operatedas a standalone plug-and-playdevice which draws power throughthe USB cable. The unit can also beoperated as a remote device thatcommunicates with the computerthrough the OM-WLS-IFC USB-towirelessinterface device. Anexternal power supply is shippedwith the device to provide powerduring remote operation.When operating as a remote device,the OM-WLS-TC communicateswith the computer through theOM-WLS-IFC device connected tothe computer’s USB port. Before theOM-WLS-TC can be operatedremotely, it needs to be connectedto the computer’s USB port and thenetwork parameters configured toestablish a wireless link with theinterface device.

    Only devices with the sameparameter settings cancommunicate with each other. Allconfigurable options are softwareprogrammable using the includedInstaCal™ utility software.LEDs on the OM-WLS-TCindicate the status ofcommunications over the wirelesslink. A LED bar graph shows thefade margin of signals receivedby the OM-WLS-TC.

    The OM-WLS-TC modules ship with an impressive array of software, including the new TracerDAQ®, a full-featured, out-of-the-box data logging, viewing, and analysis application. Driver support and detailed example programs are included for Universal Library programminglibraries for Microsoft® Visual Studio® programming languages, and otherlanguages, including DASYLab®, and ULx for NI LabVIEW® (comprehensivelibrary of VIs and example programs compatible with 32-bit and 64-bitLabVIEW v8.5 through 2012) and InstaCalTM installation, calibrationand test utility-powerful solutions for programmers and nonprogrammersalike. These modules operate under Microsoft Windows® XP (32-bit only) and VISTA/7/8 (32-bit and 64-bit) operating systems.

    SPECIFICATIONS
    ANALOG INPUTS
    A/D Converter:
    Four dual 24-bitsigma delta A/D converters
    Input Isolation:500 Vdc minbetween field wiring and USB interface
    Number of Channels:8differential thermocouple inputs
    Differential Input Voltage Range:±0.080V
    Absolute Maximum Input Voltage:±25V (power on),±40V (power off)
    Throughput Rate:2 samples/secmax for all active channels
    Input Impedance:5 GΩ min
    Input Leakage Current: 105 nA max (with open thermocouple detection enabled)
    Normal Mode Rejection Ratio:90 dB min
    Common Mode Rejection Ratio:100 dB min
    Warm-Up Time:30 minutes max
    Open Thermocouple Detection: Automatically enabled when a channel
    is configured for a thermocouple sensor
    CJC Sensor Accuracy: ±0.25°C typical, ±0.5°C max (15 to 35°C);
    -1.0 to 0.50°C max(0 to 70°C)

    DIGITAL I/O
    Digital I/O Channels:
    8
    Type: CMOS
    Configuration: Each DIO bit can beindependently configured for input oroutput.
    Power on reset is input modeunless bit is configured for alarm
    Pull-Up/Pull-Down Configuration: All pins pulled up to 5V via 47 kΩresistors (default).
    Pull-down to ground (GND) also available
    Digital I/O Transfer Rate
    (Software Paced):
    Digital Input:
    50 port reads or single bit reads persecond (typical)
    Digital Output:100 port writesor single bit writes per second (typical)
    Input High Voltage: 2.0V min, 5.5V absolute max
    Input Low Voltage:0.8V min, -0.5V absolute min
    Output High Voltage:0.7V max (IOL = 2.5 mA)
    Output Low Voltage:3.8V min (IOH = -2.5 mA)
    Temperature Alarms:8 (one per digital I/O line)


    WIRELESS COMMUNICATIONS
    Protocol:
    IEEE 802.15.4, ISM 2.4 GHz
    Range: Up to 50 m (150') indoor/urban; up to 1/2 mile
    (750 m) outdoor line-of-sight
    Transmit Power: 10 mW (10 dBm)
    Receiver Sensitivity: -100 dBm (1% packet error rate)
    RF Channels: 12 direct sequencechannels available,
    channels 12-23 (2.410-2.465 GHz), software selectable
    Addressing: 16-bit PAN (personal area network)
    IDs per channel(software selectable)
    Encryption: 128-bit AES (software selectable)

    GENERAL
    Memory:
    EEPROM
    Microcontroller: Three highperformance8-bit RISC microcontrollers
    Power Supply Voltage (Supplied by USB Port):4.75V min to 5.25V max
    Power Supply Current (Supplied by USB Port):500 mA max
    User Output Voltage (+5V): 4.75Vmin to 5.25V max, 10 mA max
    (connected to self-powered hub)
    Isolation: 500 Vdc minmeasurement system to PC
    Wireless CommunicationsOperation Supply Current:500 mA max
    (ac adaptor requiredfor remote wireless communicationsoperation)
    USB Device Type: USB 2.0 (full-speed)
    Device Compatibility: USB 1.1, USB 2.0
    USB Cable Length: 3 m (10') max
    Dimensions:127 L x 89 W x 36 mm H (5.0 x 3.5 x 1.4")
    Input Connections: Screw terminal blocks (accept 16 to 30 AWG wire)
    Operating Temperature:0 to 50°C (32 to 122°F), 0 to 90% RH non-condensing
    Storage Temperature: -40 to 85°C (-40 to 185°F)
    Weight: 180 g (6.4 oz)















































暂无内容提供
暂无内容提供

联系方式

中国自动化网安全提示,在购买供应商商品时,请一定要先审核好企业信息是否真实,谨防网上诈骗。
公司名称:Omega工业测量(中国)
联系人: 王先生
联系电话:02161973664
手机号:
传 真:
电子信箱:kevin.wang@cn.omega.com
公司网站:http://cn.omega.com
公司地址:上海市宜山路1698号102单元
留言反馈
  • 评价:

  • 关于:

  • 联系人:

  • 联系电话:

  • 联系邮箱:

  • 需求意向:

  • 验证码:

    看不清楚?

  • 在线咨询
X
下载企业APP

成为企业会员免费生成APP!